| Properties | Testing Condition | Standrad | Unit | Typical Value DAM |
| Density | 23℃ | ISO 1183-1 | G/CM³ | 1.65 |
| Moisture content | 105℃,30min | ISO 3344 | % | 0.3 |
| Moulding shrinkage | 60×60×2mm (Material Temp. 270℃, Mould Temp. 80℃) |
ISO 294-4 | % | - |
| Parallel shrinkage | 23℃,50%RH,24H | ISO 294-4 | % | 0.2-0.4 |
| Transverse shrinkage | 23℃,50%RH,24H | ISO 294-4 | % | 0.5-0.7 |
| Tensile strength | 2mm/min | ISO 527-1 | MPa | 60 |
| Tensile strain at break | 2mm/min | ISO 527-1 | % | 1.8 |
| Flexural strength | 2mm/min | ISO 178 | MPa | 94 |
| Flexural modulus | 2mm/min | ISO 178 | MPa | 6200 |
| Charpy notched impact strength | 23℃,1J | ISO 179-1 | kJ/㎡ | 5 |
| Charpy unnotched impact strength | 23℃,4J | ISO 179-1 | kJ/㎡ | 23 |
| Thermal conductivity | 80℃ | ASTM 1461-E | W/(m·K) | 0.70 |
| Heat deflection temperature | 1.8Mpa | ISO 75-1 | ℃ | 150 |
| Glow wire test | 1.0mm | IEC 60695 | ℃ | 650 |
| Comparative tracking index | 3mm,Solution A | IEC 60112 | V | 600 |